Melsec Monitor v2.1.4 SLMP

Bridge Offline
Disconnected
Polling: 0.0 fps
🌐
Download PC Bridge (v2.1.4)
PLC Connection Settings
🔬 GX Simulator
GX Simulator Direct Link

Select your simulator engine below, run Simulation in GX Works, then click connect.

Connection Status
Status: Offline
Target: -
Polling FPS: 0.0 fps
Total Polls: 0
📋 Quick Start Guide
1. GX Simulator3: Select iQ-R or iQ-F, start simulation in GX Works3, then click Connect to GX Simulator3.
2. Physical PLC: Enter your PLC IP address and port, then click Connect.
3. Device Monitor: View live registers, write values, and monitor data in real time.
🤖 AI Agent (MCP) Natural Language Control 127.0.0.1:8765/mcp

Connect Claude, ChatGPT, Cursor, Antigravity, or VS Code to open pages, connect PLCs, switch tabs, and read/write registers by voice or chat.

🔍
Auto-saved
Move Device / Label Current Value Updated Address Type VID Comment Description Delete
Total: 8 items
Single Device Write
⚠ Writing directly to PLC registers. Ensure parameters are verified to avoid equipment malfunction.
ℹ Target: D100 (1 Word)
Write to Selected Monitor Item
Select an active monitored tag and input value to write directly.
Batch Write Queue
Address Value Delete
Main Screen
0 Widgets | MC 3E Live Sync
0 Widgets | HMI

🏷️ PLC Backup Analyzer

No Folder Loaded

Offline analyzer for GX Works3 BackupData. Inspect snapshot stored values and all project symbol definitions.

📁🏷️

Drop 'BackupData' Folder or Label Files Here

Directly open the GX Works3 BackupData directory (containing LabelChg_before.csv, GVLabelData.xml, LGVLabelData.xml, GlobalLabelData_before/*.xml) to inspect offline stored values and symbol maps.

SECS/GEM Connection Settings
Semiconductor Equipment Standard (SEMI E5/E30). Reports PLC register data to Host (MES).
VID Mapping (PLC Data ➔ GEM Variable)
VID Tag Name Address Value Delete
System Logs
MC 3E Packet Log
Time Dir Command Target Device Size Elapsed Status Raw Packet HEX
800px

Mitsubishi MELSEC SLMP & MC Protocol 3E Engineering Guide

🚀 Prerequisite Step 1: Download & Launch GoGG PC Bridge

Before connecting to a physical MELSEC PLC or running the internal PLC communication simulator, you must download the GoGG PC Hardware Bridge and launch it on your local PC. Because standard web browsers enforce security sandboxes preventing direct raw TCP/IP socket connections to industrial automation hardware, the local Bridge agent (Bridge.exe) establishes a high-performance local gateway on your computer (127.0.0.1:8765) that relays commands to your PLC equipment or local simulation engine without burdening any remote servers.

📥 Download Bridge (.zip) v2.1.4 Extract archive and run Bridge.exe.
⚠️ Important Notice: Intended Use & Commercial Disclaimer

Personal Development & Testing Purpose Only: The GoGG PC Hardware Bridge (Bridge.exe) and browser-based PLC communication suites are designed and provided strictly for individual engineering development, educational research, offline simulation, and laboratory testing purposes. They are NOT certified or rated for commercial production environments, automated factory lines, high-risk manufacturing operations, or life-safety machinery. Any application in commercial facilities or live manufacturing systems is conducted solely at the user's own discretion and risk. GoGG and its developers assume zero responsibility or legal liability for any equipment damage, production downtime, operational interruption, financial losses, or adverse consequences resulting from the use or misuse of this software.

Melsec Monitor is a browser-based PLC diagnostics, device watch, and interactive web HMI studio designed for Mitsubishi Electric MELSEC programmable logic controllers, including the iQ-R Series, iQ-F (FX5U) Series, Q Series, and L Series. Engineers can connect to physical PLC hardware over Ethernet or test ladder logic against local PLC simulations directly from the browser workspace.

1. Quick Start & Connection Workflow

Setting up a live monitoring session takes less than a minute using the Connection tab:

  1. Launch the Local Bridge: Download and run Bridge.exe on your Windows PC. The header indicator will switch to Bridge Connected as soon as the local helper is active.
  2. Select Target Mode: Choose between a physical Ethernet PLC connection (entering your PLC IP address and communication port) or local simulator mode for offline ladder testing.
  3. Connect & Verify: Click Connect to begin polling. The live frame rate badge in the top header confirms active communication and response timing.

2. Supported PLC Device Families & Data Formats

The Device Monitor tab supports standard Mitsubishi Electric bit relays and word registers alongside project global labels and structured tags:

3. Multi-Sheet Watchlists, Inline Editing & Autocomplete

During equipment commissioning and sequence debugging, engineers often track dozens of signals across multiple machine stations:

4. Interactive Web HMI Touch Panel Builder

The HMI tab lets you build custom operator control panels directly in the browser without installing external screen design software:

5. Project Label Management & CSV Export / Merge Utilities

Working with symbolic tags and structured variables is streamlined through built-in client-side project tools:

6. AI Agent & Model Context Protocol (MCP) Integration

The GoGG PC Hardware Bridge (Bridge.exe) includes a local Model Context Protocol (MCP) interface supporting both local HTTP (http://127.0.0.1:8765/mcp) and standard input/output (Bridge.exe --mcp) connections. Desktop AI coding and engineering assistants—such as Claude Desktop, Cursor, Google Antigravity, and VS Code—can assist engineers by connecting to simulation sessions, organizing watchlists, and reading or writing test registers through natural language commands.

7. Frequently Asked Questions (FAQ)

Q: Can I test my PLC program using only a simulator on my PC?
A: Yes. Start your PLC simulation in your engineering software, launch Bridge.exe, select the corresponding simulator option in the Connection tab, and click Connect to monitor and toggle devices in real time.

Q: Why can I read PLC values, but writing a value is rejected?
A: If online changes or external device write permissions are disabled in the PLC\'s communication parameters, the CPU operates in read-only mode for external tools. Enable external write access in your PLC Ethernet port configuration and update the PLC parameters to allow two-way writes.

Q: Are my loaded PLC project files or tag lists shared online?
A: Never. All file inspection, tag autocomplete, and CSV exports run entirely inside your local browser session. No project files or tag names are uploaded to any server.

🪟 Melsec Monitor Standalone for Windows (24-Hour Offline Trial)

Need to test in isolated factory cleanrooms or offline facilities without launching a web browser? Download the standalone Windows executable. The communication bridge and monitoring suite are integrated into a single application. Includes a 24-hour free trial period; when expired, simply revisit gogg.gg to download the latest edition.

💡
Recommended: Use the Web Version! The web edition at gogg.gg provides unlimited access with no time limits. All new features and updates are always deployed to the web version first, so using the web version directly is highly recommended unless you require an offline isolated cleanroom environment.
🪟 Download for Windows (.zip) v2.1.4 ⏱️ 24-Hour Trial: Valid for 24 hours. Revisit gogg.gg anytime to renew.
💬 Community Discussion & Feedback

Share your PLC setup experiences, report field issues, or ask questions about Mitsubishi SLMP 3E integration.

Trademark Notice: MELSEC, iQ-R, GX Works, and SLMP are registered trademarks of Mitsubishi Electric Corporation. This application is an independent third-party industrial utility and is not affiliated with, endorsed by, or sponsored by Mitsubishi Electric Corporation.

Legal & Usage Disclaimer: This application and the integrated communication engine are intended strictly for personal development, simulation, and experimental testing. Not authorized or certified for commercial production lines or safety-critical industrial operations. The authors disclaim all liability for any damages or downtime arising from its use.